+7(495) 918-16 06 +7(495) 918-16 27

  • English
  • Русский

“CABLE AND WIRES” JOURNAL - 2025 #2

Ссылка на номер в Научной электронной библиотеке ELIBRARY.RU


DOI: 10.62994/2072-215X.2025.19.82.001

E.B. Vasiliev, Cand. Sc. (Economics), Full Member of the RF Academy of Electrotechnical Sciences, Chairman of the Board of Directors of JSC VNIIKP, Vice-President of the Electrocable Association

THE CABLE INDUSTRY AND CABLE INDUSTRY WORKERS DURING THE GREAT PATRIOTIC WAR OF 1941–1945

Abstract. The USSR suffered enormous human and material losses during the Great Patriotic War. The Soviet people had to evacuate industrial facilities beyond the Urals and to Central Asia, and new factories and plants had to be built where none had existed before.

The cable products were badly needed at the front, and it took the cable workers enormous effort to solve this problem.  The industry was headed by competent and strong leaders who led the labour force.

Key words: war, evacuation, field wires, construction of plants, heroism of home front workers, production for the front, cable plants, history of the military cable industry


ANALYSES AND FORECASTS


DOI: 10.62994/2072-215X.2025.92.45.002

RESULTS OF THE ACTIVITIES OF THE ELECTROCABLE ASSOCIATION COMPANIES IN 2024

N.V. Sakharova, General Director of the Electrocable Association

Abstract. The article was prepared based on the materials of the 86th general meeting of the Electrocable Association members. The main performance results of the Electrocable Association enterprises in 2024 are provided. The relationship between the dynamics of changes in cable production volumes and the main macroeconomic indicators of the country's economic development is shown. The industry showed 1% growth against the previous year, which is significantly lower than previously predicted. Data on the production volumes of the main item groups of cable products are presented.

Key words: industrial production index, dynamics of cable production volumes, energy wire and cable production, production of wire and cable components for machines, equipment and devices, telecommunication wire and cable production, transport wire and cable production.


SCIENCE AND TECHNOLOGY  


DOI: 10.62994/2072-215X.2025.30.15.003

 

FAILURES OF HIGH VOLTAGE CABLE SYSTEM TERMINATIONS AND IMPROVEMENT OF PARTIAL DISCHARGE MONITORING SYSTEMS

 

S.S. Vetlugaev, Cand. Sc. (Engineering), Senior Research Scientist, JSC VNIIKP;

A.N. Gorobets, Cand. Sc. (Engineering), Head of Section, JSC VNIIKP;

A.M. Kudlaev, Chief Expert of the Department of technical regulation of PAO RusHydro;

L.E. Makarov, Cand. Sc. (Engineering), Leading Research Scientist, JSC VNIIKP;

V.L. Ovsienko, Cand. Sc. (Engineering), Deputy Division Manager, Head of Laboratory, JSC VNIIKP;

T.R. Khaziakhmetov, Director of the Department of technical regulation of PAO RusHydro

Abstract. The failures of HV cable systems terminations and improvements of partial discharge monitoring in insulation are being considered in that context.

Key words: cable system, termination, joint accessories, elastomeric elements, assembling, stress cone, electrical breakdown, partial discharges


DOI: 10.62994/2072-215X.2025.24.55.004

STUDY OF THERMAL AGING RESISTANCE OF RUBBER CABLE JACKETS MADE OF POLYCHLOROPRENE AND CHLORINATED POLYETHYLENE

S.M. Dudnik, postgraduate student, engineer JSC VNIIKP;

K.A. Zvezdenkov, Cand. Sc. (Engineering), Head of the laboratory JSC VNIIKP;

T.A. Merkulova, Cand. Sc (Engineering), senior researcher JSC VNIIKP;

M.V. Kolykhaeva, Cand. Sc (Engineering), senior researcher JSC VNIIKP;

D.A. Kharchenko, Head of the laboratory JSC VNIIKP;

D.V. Novikov, Cand. Sc (Engineering), Head of the department JSC VNIIKP, corr. member of the Academy of Electrotechnical Sciences of Russian Federation

Abstract. The article represents the results of long-term thermal aging of the studied rubbers at different temperatures. It was observed what heat resistance of rubber based on chlorinated polyethylene is significantly higher in compаrison with rubber based on polychloroprene. The activation energies of both rubbers were determined.

Key words: cross-linked cable materials, polychloroprene rubber, chlorinated polyethylene rubber, thermal aging, activation energy, rubber cable jacket


DOI: 10.62994/2072-215X.2025.58.33.005

WATER SWELLABLE WATER BLOCKING TAPES FOR CABLE PRODUCTS. STUDIES ON COMPONENTS SELECTION, BASIC PARAMETERS, INFLUENCING FACTORS AND MEASUREMENT METHODS

I.A. Ovchinnikova, Dr. Sc. (Engineering), full member of the RF Academy of Electrotechnical Sciences, Director of Research Area, JSC VNIIKP;

E.V. Lebedeva, Head of the Laboratory, JSC VNIIKP;

P.A. Semenov, Head of the Department, JSC VNIIKP

R.E. Vasiliev, Cand. Sc. (Engineering), full member of the RF Academy of Electrotechnical Sciences, General Director, JSC Electroprovod

Abstract. This article provides a brief information on the water swellable water blocking materials composition, its basic parameters list, describes the basic parameters measuring developed methodology and individual measurement results, and shows the material components properties and other factors influence on its parameters.

Key words: water swellable water blocking tapes, superabsorbent polymers, water absorption speed, water absorption capacity


PAGES OF HISTORY


PROFESSOR. 

REMEMBERING I.B. PESHKOV


INDUSTRY NEWS


THE MEETING OF THE TELECOMMUNICATION CABLES SECTION OF THE ELECTROCABLE ASSOCIATION IN VELIKY NOVGOROD


JUBILEES


S.V. ZINUKOV is celebrating his 60th birthday